자동로그인
 

현재위치 : Home > 전기 및 전력측정기 > TES

 
AFLEX -3005 Flexible Power Quality Tester
    · 고객선호도 :
    · 제조사 : TES
    · 원산지 : 대만
    · 판매가격 :
    · 포 인 트 :
    · 수 량 :


회원이 되시면 가격변동정보, 신제품, 특판제품, 기술정보등 다양한
뉴스정보를 보내드립니다.
배송은 평균 2~3일정도 예상됩니다.
                    (0)                     (0)                     (0)

AFLEX-3003 Flexible VA Harmonics Tester

AFLEX -3005 Flexible Power Quality Tester


Power Analysis (3005)

  • W, KW, H.P.
  • VA ,KVA, VAR, KVAR
  • PF, Phase Angle( Φ )
  • Energy (WH, KWH)
  • Dual displays (W+PF, VA+KVAR)
  • Balanced 3 Φ Power Quality and Sequence

Harmonics Analysis

  • True RMS (V and A)
  • 3000 A
  • Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude
  • Analysis of % THD-F and C.F.
  • Fast Peak Function (33μs and 39μs)
  • Programmable PT (1 to 250 )ratios
  • Auto - Power - Off : 30 Minutes

Flexible probe , different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm

 

AC Watt (50 or 65 Hz, PF 0.5 to 1, CT=1) AFLEX-3005 only

Range
Resolution
Accuray of reading
100.0 - 999.9 W
0.1 W
2% of range
1.000 - 9.999 KW
0.001 KW
2% of range
10.00 - 99.99 KW
0.01 KW
2% of range
100.0 - 999.9 KW
0.1 KW
2% of range
1000 - 9999 KW
1 KW
2% of range

AC Voltage(50 or 65 Hz, ,Auto Range, True RMS)

Range
Resolution
Accuracy of reading
4.0 V - 600 V
0.1 V
±0.5% ± 5dgts

Harmonics of AC Current in % and Magnitude(1 to 50th order)

Range
Resolution
Accuracy in %
Accuracy of Magnitude
1-20th
0.1%
±2%
±2% of reading ±0.4A
21st-50th
0.1%
±4% of reading ±2.0%
±4% of reading ± 0.4V

AC Current(50 or 65 Hz ,Auto Range, True RMS)

Range
Resolution
Accuracy of reading
0 - 300.0 A
0.1 A
1% of range
300.0 - 999.9 A
0.1 A
1% of range
1000 - 3000 A
1 A
1% of range

Harmonics of AC Voltage in % and Magnitude(1 to 50th order)

Range
Resolution
Accuracy in %
Accuracy of Magnitude
1-20th
0.1%
±2%
±2% ±0.5V
21st-50th
0.1%
±4% of reading ±2.0%
±4% of reading ± 0.5V

Total Harmonics Distortion(%THD-F,1 to 50th order)

Range
Resolution
Accuracy of reading
0.0-20%
0.1%
±2%
20-100%
0.1%
±6% of reading ±1%
100-999.9%
0.1%
±10% of reading ±1%

 

번호 제목 작성자 작성일 평가점수
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다.
 
* 이 상품을 사용해 보셨다면 사용후기를 써 주십시오.
번호 제목 작성자 작성일 답변
이 상품에 대한 질문이 아직 없습니다.
궁금하신 사항은 이곳에 질문하여 주십시오.
 
* 이 상품에 대한 궁금한 사항이 있으신 분은 질문해 주십시오.
이 상품과 관련된 상품이 없습니다.
 
회사소개 | 서비스이용약관 | 개인정보취급방침
주소 : 경기도 성남시 중원구 둔촌대로 474, 708호 (상대원동 선텍시티1)
Tel : 031-777-1588 / Fax : 031-777-1587 / 개인정보관리책임자 : 관리자