        | Ashcroft deadweight testers provide an easy means of precisely generating pressure an accuracy |  | 
  
    
      | Ashcroft deadweight  
        testers provide an easy means of precisely generating pressure to an  
        accuracy of 0.1% of reading. 1305 units are available for operating  
        ranges up to 10,000 psi. They are ideal in use of calibrating, setting,  
        testing, and repairing pressure measurement and control devices. Each  
        unit is traceable to the National Institute of Standards and Technology  
        assuring instrument accuracy. These pressure systems are designed to be field portable. A single  
        carrying case holds the pressure generation pump as well as the  
        necessary tools and accessories. A second box contains the weights used  
        for pressure generation (10,000 units require 2 boxes of weights).
 Ashcroft deadweight testers qualify as primary standards for pressure  
        calibration. The pump is a two-stage hydraulic pressure generator. A  
        built-in shuttle valve allows for rapid pressure increase at low  
        pressures. The rate of increase, at pump cycle, can be reduced at higher  
        pressures in order to minimize resistance. This is accomplished by  
        simply repositioning the two position shuttle valve. With the shuttle  
        valve in the high pressure position, increasing pressure even when near  
        the 10,000 psi upper limit can be quickly and easily accomplished.  
        Final, precise adjustment is accomplished through the use of an integral  
        vernier adjustment knob.
 The unit is provided with two piston cylinder assemblies: A low pressure  
        piston for pressure ranges from 15 to 2000 psi and a high pressure unit  
        for pressures from 75 to 10,000 psi. The high pressure piston has an  
        area of 1/80th of a square inch while the low pressure piston has an  
        area of 1/16th of a square inch. Weights are provided for pressure  
        increments of 5, 10, 20, 25, 40, 50, 100, 200, and 500 psi (depending on  
        piston in use). An optional 1 psi incremental weight is also available.  
        Ashcroft testers can be used anywhere within their operational range  
        without any change in accuracy. The same weights are used with both  
        piston and cylinder assemblies.
 The units are available for psi, bar, kg/cm2 and kPa ranges.  
        Each unit comes complete with a hand jack set (for removal of pointers  
        on gauges being calibrated), spare O-rings and all tools, accessories  
        and fittings required for normal use.
 |   
      |  |   
   
     
      |  
           
             
              |  
                  Features 
                 |   
              |  
                  Accuracy  
                    of 0.1% of reading 
                  Operating  
                    pressure of 15 psi to 10,000 psi (100 kPa to 70,000 kPa) 
                  Operating  
                    media 1305D-SAE 20 weight automotive or machine oil 1305DH-  
                    Phosphate based or glycol fluids 
                  Traceable  
                    to NIST 
                  O-Ring  
                    material 1305D-Buna-N (D series) 1305DH- Ethylene propylene  
                    (DH series) 
                  Stainless  
                    steel piston and cylinder material 
                  Non-metallic  
                    die-cast zinc weight material 
                  Reservoir  
                    volume approximately 1.5 pints (0.7 liter) |   
              |  |  |   
   
     
      | CAT  
        NO. |  | MODEL |  | DEscRIPTION |  | AVAIL |  | PRICE |  
  
    
      | AS130200 |  | 1305D-10 |  | PRECISION  
        DEAD WEIGHT TESTER |  | Yes |  | 6,469,200 |  
  
    
      | Low  
        Pressure Range: |  | 15-200psi |   
      | High  
        Pressure Range: |  | 75-1000psi |   
   
     
      | AS130201 |  | 1305D-20 |  | PRECISION  
        DEAD WEIGHT TESTER |  | Yes |  | 6,966,000 |  
  
    
      | Low  
        Pressure Range: |  | 15-400psi |   
      | High  
        Pressure Range: |  | 75-2000psi |   
   
     
      | AS130202 |  | 1305D-30 |  | PRECISION  
        DEAD WEIGHT TESTER |  | Yes |  | 7,117,200 |  
  
    
      | Low  
        Pressure Range: |  | 15-600psi |   
      | High  
        Pressure Range: |  | 75-3000psi |   
   
     
      | AS130203 |  | 1305D-50 |  | PRECISION  
        DEAD WEIGHT TESTER |  | Yes |  | 7,333,200 |  
  
    
      | Low  
        Pressure Range: |  | 15-1000psi |   
      | High  
        Pressure Range: |  | 75-5000psi |   
   
     
      | AS130204 |  | 1305D-100 |  | PRECISION  
        DEAD WEIGHT TESTER |  | Yes |  | 8,985,600 |  
  
    
      | Low  
        Pressure Range: |  | 15-2000psi |   
      | High  
        Pressure Range: |  | 75-10,000psi |  |  |  |  |  |  
|  |  |  | 
        
            |  | 
                
                    | ¹øÈ£ | Á¦¸ñ | ÀÛ¼ºÀÚ | ÀÛ¼ºÀÏ | Æò°¡Á¡¼ö |  |  |  
                |  | ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù. »ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 |  |  
            |  |  |  |  |  |  |  
|  |  |  | 
        
            |  | 
                
                    | ¹øÈ£ | Á¦¸ñ | ÀÛ¼ºÀÚ | ÀÛ¼ºÀÏ | ´äº¯ |  |  |  
                |  | ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù. ±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 |  |  
            |  |  |  |  |  |  |  
|  |  |  | 
        | ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. |  |  |  |  |