ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Panel Meters > Controllers

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
CH32161 AC supply, logic heat output
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:CH32161
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The new 1/16th DIN controller provides a new level of user convenience.
The new 1/16th DIN controller provides a new level of user convenience. The scrolling text messages deliver plain language messages to let operators and engineers alike know exactly what is happening to the process.

The Load Current Transformer Input, CT input, provides the ideal method to monitor load current and provide immediate indication of load conditions. Partial load failure, heater open circuit or contactor short circuit can each be indicated by clear scrolling operator messages and relay output.

The new 3-color LCD display provides clear indication of process variables. The upper display shows the process measured value while the lower display can be set to display a range of parameters including, setpoint, time remaining and current.

The communications option provides full system integration through the industry standard modbus protocol.
 
Features
  • Quick Start Wizard makes configuration simpler that eve
  • Up to 10 text messages of 30 characters in length
  • Configurable operator interface with security access
  • CT input for partial load failure, heater failure or contactor short circuit
  • Universal inputs provide for thermocouple, 2 or 3-wire RTD, mV and mA inputs
  • Digital communications
  • Custom linearization using iTools
  • Three outputs for any combination of heating, cooling or alarm
  • Ideal for plastic extruders, small ovens, chillers, trace heating, packaging machines
 
SPECIFICATIONS
Dimensions 48W x 48H x 90D mm
Control modes PID or On/Off, heat/cool, heat only, cool only
Supply voltages 85-264Vac or 24Vac/dc (6 watts max.)
Operating ambient 0 to 50 deg C, 5% to 85% RH, non condensing
Inputs Thermocouples, Pt100 3 wire, 0-50mV, 4-20mA, 0-20mA,
Custom linearisation
Current transformer input 50mA ac into 10R
Communications Modbus, RS232, RS485 2 wire
Output ratings Relay: 2A, 264Vac resistive, Logic out: 12Vdc
Digital in contact closure or logic
Panel sealing IP65, NEMA 4X, plug-in from front panel

CAT NO. MODEL DEscRIPTION AVAIL PRICE
CH32161   ¡¡ ¡¡ AC supply, logic heat output, J thermocouple, degrees F   Yes   572,400
CH32162   ¡¡ ¡¡ AC supply, logic heat output, CT input, J thermocouple, degrees F   Yes   615,600
CH32163   ¡¡ ¡¡ AC supply, logic heat output, CT input, J thermocouple, degrees F, Modbus RS485 comms.   Yes   710,640
CH32164   ¡¡ ¡¡ AC supply, logic heat output, relay high alarm, J thermocouple, degrees F   Yes   645,600
CH32165   ¡¡ ¡¡ AC supply, logic heat output, CT input, relay high alarm, J thermocouple, degrees F   Yes   918,000

 

CH32166   ¡¡ ¡¡ AC supply, logic heat output, CT input, relay high alarm, J thermocouple, degrees F, Modbus RS485 comms.   Yes   810,000

 

CH32167   ¡¡ ¡¡ AC supply, logic heat output, relay cool output, relay high alarm, J thermocouple, degrees F   Yes   594,000

 

CH32168   ¡¡ ¡¡ AC supply, logic heat output, relay cool output, CT input, relay high alarm, J thermocouple, degrees F   Yes   710,640

 

CH32169   ¡¡ ¡¡ AC supply, logic heat output, relay cool output, CT input, relay high alarm, J thermocouple, degrees F, Modbus RS485 comms.   Yes   831,600

 

CH32170   ¡¡ ¡¡ iTools configuration software, instrument communications required   Yes   710,640
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ