        |  | DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
 DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)| 
|  |  |  | 
        | The CR4395/the CR7310 Current Sensing Relays are designed to monitor current levels in AC conductors |  | 
| The CR4395 and the CR7310 Current Sensing Relays are designed to monitor current levels in AC conductors, and provide a dry relay contact activation when the current rises above or falls below a user adjusted set point. The 4395 is for general applications, and the 7310 is UL listed for use as a component of ground fault systems. Specify remote current transformer when ordering remote sensing relay applications. (7310 only) 
 When ordering any of the above relays, time on delay (.5 to 6 sec. or 2 to 25 sec.) must be specified. |  
|  |  
SPECIFICATIONS
| 
| Features  |  
| 
Variable trip point and time delay 
Monitors currents from 10ma. to 60 AC Amps 
Electrical isolation between circuits 
Output relay rated up to 20 Amps 
LED relay status indicator 
Dead band prevents relay chatter 
Calibrated dial standard 
External current transformers available  |  
|  |  |  
| Mounting | Two 3/16" dia. clearance holes on 1 15/16" by 2 15/16" centers |  
| Operating Temp. | 500 PPM/8C |  
| Power-on delay | 0 to 50 8C |  
| Hysteresis | >100,000 Hrs |  
| Input Supply Power | 70VAC |  
| Terminal | 1/4" Quick Connect |  
| Frequency Range | 50-400 Hz |  
| Output Relay |  
| Arrangement | 1 Form C (SPDT) |  
| Contact Material | Silver-cadmium oxide |  
| Mechanical Life | 10 million operations |  
| Electrical Life | 100,000 operations |  
| Contact Resistance | 50 milliohms |  
| Contact Rating | UL508/873 & CSA |  
 
| Voltage | Load Type | N.O. Contact | N.C. Contact |  
| 240 VAC | Resistive | 20A | 10A |  
| 240 VAC | Motor | 2 HP | 1/2 HP |  
| 125 VAC | Motor | 1 HP | 1/4 HP |  
| 28 VDC | Resistive | 20A | 10A |  
 
| CAT NO. |  | MODEL |  | DEscRIPTION |  | AVAIL |  | PRICE |  
| CR43902 |  | CR4395-EH-120-70* |  | CURRENT SENSING RELAY |  | Usually ships in 7 to 10 days |  | 280,216 |  
| CR43903 |  | CR4395-EH-120-330* |  | CURRENT SENSING RELAY |  | Usually ships in 7 to 10 days |  | 270,000 |  
| CR43906 |  | CR4395-EL-120-70* |  | CURRENT SENSING RELAY |  | Usually ships in 7 to 10 days |  | 270,000 |  
| CR43911 |  | CR7310-EH-120-.01-1-l |  | Ground Fault Sensing Relay 120VAC610%, Trip Range .01 to .1 |  | Usually ships in 7 to 10 days |  | 321,840 |  
| CR43912 |  | CR7310-EH-120-70-l |  | Ground Fault Sensing Relay 120VAC610%, Trip Range .01 to .1 |  | Usually ships in 7 to 10 days |  | 321,840 |  
| CR43913 |  | CR7310-EH-120-330-l |  | Ground Fault Sensing Relay 120VAC610%, Trip Range .01 to .1 |  | Usually ships in 7 to 10 days |  | 321,840 |  
| CR43914 |  | CRGFS-100 |  | OPTIONAL Remote Ground Fault Current Transformer 1.5" Diameter window FOR Current and Ground Fault Sensing Relays |  | Usually ships in 7 to 10 days |  | 97,200   |  
| CR43915 |  | CRGFS-200 |  | OPTIONAL FOR Current and Ground Fault Sensing Relays |  | Usually ships in 7 to 10 days |  | 127,440 |  |  |  |  |  |  
|  |  |  | 
        
            |  | 
                
                    | ¹øÈ£ | Á¦¸ñ | ÀÛ¼ºÀÚ | ÀÛ¼ºÀÏ | Æò°¡Á¡¼ö |  |  |  
                |  | ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù. »ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 |  |  
            |  |  |  |  |  |  |  
|  |  |  | 
        
            |  | 
                
                    | ¹øÈ£ | Á¦¸ñ | ÀÛ¼ºÀÚ | ÀÛ¼ºÀÏ | ´äº¯ |  |  |  
                |  | ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù. ±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 |  |  
            |  |  |  |  |  |  |  
|  |  |  | 
        | ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. |  |  |  |  | 
 |  |