The ML2222 Bench Calibrator is a revolutionary new product design that offers laboratory grade accuracy at a handheld calibrator price.

¡¡

The ML2222 has user friendly control functions with direct keyboard and scroll capability for data entry. It can also be operated through an RS232, or optional IEEE interface for automated testing. The ML2000 is compatible and works with Fluke Met/Cal automated calibration software.

¡¡

The ML2222 has the ability to store up to 9 setpoints for each output range. The setpoints can be selected manually or automatically stepped at timed intervals.

¡¡

The ML2222 contains a standby/operated safety feature typically found in calibrators selling for considerably more than the ML2222. This feature protects both the operator and the calibrator from potential overload conditions.

¡¡

For superior calibration accuracy the ML2222 features Tellurium copper binding posts reducing thermal emf¡¯s to less than 1 microvolt.
Features
  • Handheld and bench multimeters
  • Analog voltage and current instruments
  • Data loggers
  • Strip chart recorders
  • Other related instruments
  • Lab Standard
  • Engineers involved in product development where sensors, A/D converters, data acquisition and process control circuitry are being developed
  • Production testing of devices that need analog signals as a stimulus
  • Process control calibrator reference instrument standards (used in plant I.E. shops)
  • Cal labs that have a heavy DC calibration workload
SPECIFICATIONS

Power Requirements

100/120/240 VAC
Remote Interface RS-232 and GPIB (488 optional)
Circuit Protection Self resetting along with conventional fuses
Warm-up Time 30 min. to best accuracy
Temperature Range
Operating 0¡ÆC to 40¡ÆC
Storage -20¡ÆC to 60¡ÆC
Stability For temps less than -18¡ÆC or greater than 28¡ÆC, 10% of accuracy spec/¡ÆC
Display 16 x 2 large character alphanumeric with LED backlight
Size Approx. 11.5" x 4.7" x 12"
Weight Approx. 5 pounds
Range Accuracy (% of Reading) (1 year spec at 23¡ÆC ¡¾5¡ÆC) Resolution Max Burden
0-100.000 mV ¡¾0.003% ¡¾3 ¥ìV 1 ¥ìV 10 mA
0-1.00000 V ¡¾0.003% ¡¾20 ¥ìV 10 ¥ìV 10 mA
0-10.0000 V ¡¾0.003% ¡¾200 ¥ìV 100 ¥ìV 10 mA
0-100.000 V ¡¾0.003% ¡¾2 mV 1 mV 1 mA
0-100.000 mA ¡¾0.01% ¡¾2 ¥ìA 1 ¥ìA 10 V

CAT NO. MODEL DEscRIPTION AVAIL PRICE
ML2222 M2000 Voltage/Current Bench Calibrator Yes 3,112,020
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ