The HR9102 is excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient. For work in the temperature range of -10°C to 122°C, the HR9102 dry-well is the industry’s choice, featuring stability to ±0.05°C. This dry-well is only four inches high and six inches wide, achieves temperatures as low as -10°C. The HR9102 has two wells so you can use one for a reference thermometer to increase accuracy. Both wells are 1/2 inch in diameter, and each has inserts available for almost any sensor size. The HR9102 also has a battery pack option that gives you approximately four hours of field use when AC power is unavailable.
These portable dry wells are the smallest, lightest, and most portable dry-wells in the industry. Despite its small size (2 1/2 inches high and 5 inches wide) and lightweight, the 9100S outperforms all other dry-wells in its class. Anyone can learn to use one in less than 15 minutes. It has a range to 375°C (707°F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.
Plug it in, switch it on, set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Benefiting from a proprietary Hart Scientific temperature controller, the HR910001, HR910011 and HR910021 have a display resolution of 0.1 degrees, an accuracy of ±0.5°C, a stability of ±0.1°C, and a stabilization time of just five minutes. |
| |
|
Features |
- Smallest dry-wells in the world
- Ranges from -10°C to 375°C
- Accuracy to ±0.5°C over full ranges, stability of ±0.05°C at 0°C
- RS-232 interface with Hart software
|
| | | SPECIFICATIONS
| |
HR910001/HR910011/HR910021 |
HR9102S |
| Range |
35°C to 375°C (95°F to 707°F) |
–10°C to 122°C (14°F to 252°F) at 23°C ambient |
| Accuracy |
±0.5°C |
| Stability |
±0.1°C at 100°C |
±0.05°C at 0°C |
| |
±0.3°C at 375°C |
±0.1°C at 122°C |
| Well-to-Well Uniformity |
±0.2°C with sensors of similar size at equal depths within wells |
| Heating Times |
35° to 375°C: 9.5 minutes |
ambient to 100°C: 10 minutes |
| Stabilization |
5 minutes |
7 minutes |
| Cooling Times |
375°C to 100°C: 14 minutes |
ambient to 0°C: 10 minutes |
| Well Depth |
4 inches (102 mm); 1/16" (1.6 mm) hole is 3.5" (89 mm) deep |
4 inches (102 mm) |
| Removable Inserts |
N/A |
Available in sizes from 1/16" (1.6 mm) to 7/16" (11.1 mm)[1/4" (6.4 mm) and 3/16" (4.8 mm) included] |
| Computer Interface |
RS-232 included with free Interface-it software |
| Power |
115 VAC (±10%), 1.5 A or 230 VAC (±10%), 0.8 A, specify, 50/60 Hz, 175 W |
94-234 VAC (±10%), 50/60 Hz, 60 W; or 12 VDC |
| Size |
2.25" H x 4.9" W x 5.9" D (57 x 125 x 150 mm) |
3.9" H x 5.5" W x 6.9" D (99 x 140 x 175 mm) |
| Weight |
2 lb. 3 oz. (1 kg) |
4 lb. (1.8 kg) |
| NIST-Traceable Calibration |
Data at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C |
Data at –10°C, 25°C, 50°C, 55°C, 100°C, and 122°C |
| CAT NO. |
 |
MODEL |
 |
DEscRIPTION |
 |
AVAIL |
 |
PRICE |
| HR910001 |
|
9100SA |
|
HANDHELD DRY-WELL CALIBRATOR, HDRC BLOCK A, °C/°F |
|
Yes |
|
2,469,420 |
| HR910011 |
|
9100BC |
|
HANDHELD DRY-WELL CALIBRATORS, HDRC BLOCK B, °C/°F |
|
Yes |
|
2,469,420 |
| HR910021 |
|
9100CC |
|
HANDHELD DRY-WELL CALIBRATOR, HDRC BLOCK C, °C/°F |
|
Yes |
|
2,469,420
|
| HR9300 |
|
9300 |
|
OPTIONAL RUGGED CARRYING CASE FOR 9100 DRY-WELL CALIBRATORS FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
110,160
|
| HR9102 |
|
9102 |
|
OPTIONAL LOW TEMP. HANDHELD DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
4,030,020
|
| HR9308 |
|
9308 |
|
OPTIONAL RUGGED CARRYING CASE FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
128,520
|
| HR9312 |
|
9312 |
|
OPTIONAL BATTERY PACK FOR 9102 CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
963,900
|
| HR31020 |
|
3102-0 |
|
OPTIONAL BLANK INSERT FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
128,520
|
| HR31021 |
|
3102-1 |
|
OPTIONAL INSERT, 1/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
146,880
|
| HR31022 |
|
3102-2 |
|
OPTIONAL INSERT, 1/8" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
146,880
|
| HR31028 |
|
3102-8 |
|
OPTIONAL INSERT, 5/32" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
146,880
|
| HR31023 |
|
3102-3 |
|
OPTIONAL INSERT, 3/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
146,880
|
| HR31024 |
|
3102-4 |
|
OPTIONAL INSERT, 1/4" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
146,880
|
| HR31025 |
|
3102-5 |
|
OPTIONAL INSERT, 5/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
146,880
|
| HR31026 |
|
3102-6 |
|
OPTIONAL INSERT, 3/8" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
146,880
|
| HR31027 |
|
3102-7 |
|
OPTIONAL INSERT, 7/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells |
|
Yes |
|
146,880
| | |
|
|
 | |
 |
|
 |
|
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다. |
|
 |
|
 |
|
|
 | |
 |
|
 |
|
이 상품에 대한 질문이 아직 없습니다.
궁금하신 사항은 이곳에 질문하여 주십시오. |
|
 |
|
 |
|
|
|