The HR9102 is excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient. For work in the temperature range of -10°C to 122°C, the HR9102 dry-well is the industry’s choice, featuring stability to ±0.05°C. This dry-well is only four inches high and six inches wide, achieves temperatures as low as -10°C. The HR9102 has two wells so you can use one for a reference thermometer to increase accuracy. Both wells are 1/2 inch in diameter, and each has inserts available for almost any sensor size. The HR9102 also has a battery pack option that gives you approximately four hours of field use when AC power is unavailable.

These portable dry wells are the smallest, lightest, and most portable dry-wells in the industry. Despite its small size (2 1/2 inches high and 5 inches wide) and lightweight, the 9100S outperforms all other dry-wells in its class. Anyone can learn to use one in less than 15 minutes. It has a range to 375°C (707°F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.

Plug it in, switch it on, set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Benefiting from a proprietary Hart Scientific temperature controller, the HR910001, HR910011 and HR910021 have a display resolution of 0.1 degrees, an accuracy of ±0.5°C, a stability of ±0.1°C, and a stabilization time of just five minutes.
 
Features
  • Smallest dry-wells in the world
  • Ranges from -10°C to 375°C
  • Accuracy to ±0.5°C over full ranges, stability of ±0.05°C at 0°C
  • RS-232 interface with Hart software
 
SPECIFICATIONS
  HR910001/HR910011/HR910021 HR9102S
Range 35°C to 375°C (95°F to 707°F) –10°C to 122°C (14°F to 252°F) at 23°C ambient
Accuracy
±0.5°C
Stability ±0.1°C at 100°C ±0.05°C at 0°C
  ±0.3°C at 375°C ±0.1°C at 122°C
Well-to-Well Uniformity
±0.2°C with sensors of similar size at equal depths within wells
Heating Times 35° to 375°C: 9.5 minutes ambient to 100°C: 10 minutes
Stabilization 5 minutes 7 minutes
Cooling Times 375°C to 100°C: 14 minutes ambient to 0°C: 10 minutes
Well Depth 4 inches (102 mm); 1/16" (1.6 mm) hole is 3.5" (89 mm) deep 4 inches (102 mm)
Removable Inserts N/A  Available in sizes from 1/16" (1.6 mm) to 7/16" (11.1 mm)[1/4" (6.4 mm) and 3/16" (4.8 mm) included]
Computer Interface
RS-232 included with free Interface-it software
Power 115 VAC (±10%), 1.5 A or 230 VAC (±10%), 0.8 A, specify, 50/60 Hz, 175 W 94-234 VAC (±10%), 50/60 Hz, 60 W; or 12 VDC
Size 2.25" H x 4.9" W x 5.9" D (57 x 125 x 150 mm) 3.9" H x 5.5" W x 6.9" D (99 x 140 x 175 mm)
Weight 2 lb. 3 oz. (1 kg) 4 lb. (1.8 kg)
NIST-Traceable Calibration Data at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C Data at –10°C, 25°C, 50°C, 55°C, 100°C, and 122°C

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
HR910001   9100SA   HANDHELD DRY-WELL CALIBRATOR, HDRC BLOCK A, °C/°F   Yes   2,469,420
HR910011   9100BC   HANDHELD DRY-WELL CALIBRATORS, HDRC BLOCK B, °C/°F   Yes   2,469,420
HR910021   9100CC   HANDHELD DRY-WELL CALIBRATOR, HDRC BLOCK C, °C/°F   Yes   2,469,420

 

HR9300   9300   OPTIONAL RUGGED CARRYING CASE FOR 9100 DRY-WELL CALIBRATORS FOR Hart Scientific Handheld Dry Wells   Yes   110,160

 

HR9102   9102   OPTIONAL LOW TEMP. HANDHELD DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   4,030,020

 

HR9308   9308   OPTIONAL RUGGED CARRYING CASE FOR Hart Scientific Handheld Dry Wells   Yes   128,520

 

HR9312   9312   OPTIONAL BATTERY PACK FOR 9102 CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   963,900

 

HR31020   3102-0   OPTIONAL BLANK INSERT FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   128,520

 

HR31021   3102-1   OPTIONAL INSERT, 1/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   146,880

 

HR31022   3102-2   OPTIONAL INSERT, 1/8" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   146,880

 

HR31028   3102-8   OPTIONAL INSERT, 5/32" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   146,880

 

HR31023   3102-3   OPTIONAL INSERT, 3/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   146,880

 

HR31024   3102-4   OPTIONAL INSERT, 1/4" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   146,880

 

HR31025   3102-5   OPTIONAL INSERT, 5/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   146,880

 

HR31026   3102-6   OPTIONAL INSERT, 3/8" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   146,880

 

HR31027   3102-7   OPTIONAL INSERT, 7/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Hart Scientific Handheld Dry Wells   Yes   146,880

 

번호 제목 작성자 작성일 평가점수
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다.
 
* 이 상품을 사용해 보셨다면 사용후기를 써 주십시오.
번호 제목 작성자 작성일 답변
이 상품에 대한 질문이 아직 없습니다.
궁금하신 사항은 이곳에 질문하여 주십시오.
 
* 이 상품에 대한 궁금한 사항이 있으신 분은 질문해 주십시오.
이 상품과 관련된 상품이 없습니다.
DAVIS 종합 계측기 - 한국대리점 코린스계기(주)
 
회사소개 | 서비스이용약관 | 개인정보취급방침
주소 : 경기도 성남시 중원구 둔촌대로 474, 708호 (상대원동 선텍시티1)
Tel : 031-777-1588 / Fax : 031-777-1587 / 개인정보관리책임자 : 관리자
사업자 등록번호 : 116-81-31753 / 통신판매업신고 : 2005-경기성남-0886호
대표자 : 홍영화 / 운영자 : 윤상미
상호 : 주식회사 코린스 / Copyright ⓒ 2002. All Rights Reserved.
가입사실확인