      | The HT100 &  
        HT120 were developed to handle the extreme temperatures and conditions  
        previously impossible for a Datalogger. With a temperature monitoring  
        range of -40 to +257¡ÆF and waterproof case constructed of stainless  
        steel, the HT100 & HT120 are ready for your toughest applications.  
        Perfect for HACCP, FDA, pharmaceutical, medical, agricultural, and oil  
        & gas applications. Compatible with our newest presentation  
        software. |  
      
     
      |   |  
      
   
  
 
   
     
       
         
           
             
              |  
                  
                  Features 
                  
               |  
              
             
               
                 
                  - Real  
                    time monitoring and graphing 
                  
 - Faster  
                    downloads 
                  
 - Makes  
                    exporting to other software a snap
  
                  
               |  
              
             
              |   |  
              
           
          
         
           
             
              |  
                  
                  DK976517 
                  
               |  
              
             
               
                 
                  - Compact,  
                    only 3.69" x 0.6875" DIA. Perfect for tight  
                    locations, oil & Gas and process applications
  
                  
               |  
              
             
              |   |  
              
           
          
       |  
      
   
  
 
   
     
       
         
           
             
              |  
                  
                  DK976516 
                  
               |  
              
             
               
                 
                  - Features  
                    a 2.5" x 3/16" DIA probe. Perfect for monitoring  
                    liquids and solids in freezers, autoclaves, incubators and  
                    baths. 
                  
 - Also  
                    perfect for monitoring soil and sand temperatures
  
                  
               |  
              
             
              |   |  
              
           
          
         
           
             
              |  
                  
                  DK976525 
                  
               |  
              
             
               
                 
                  - Features  
                    a 5" x 0.11" DIA probe. Made to meet the  
                    requirements of HACCP. 
                  
 - Monitor  
                    meat in smokers and coolers and much more
  
                  
               |  
              
             
              |   |  
              
           
          
       |  
      
   
  
SPECIFICATIONS 
 
   
     
      | Temperature Range |  
      -40 to +257 ¡ÆF  
        (-40 to +125 ¡ÆC) |  
      
     
      | Temperature  
        Accuracy |  
      ¡¾1.8¡ÆF (¡¾1¡ÆC)  
        over range -4 to +212 ¡ÆF (-20 to +100 ¡ÆC) |  
      
     
      |   |  
      ¡¾3.6 ¡ÆF (¡¾2¡ÆC)  
        over range -40 to +257 ¡ÆF (-40 to +125 ¡ÆC) |  
      
     
      | Sensor Type |  
      Internal Thermistor |  
      
     
      | Battery Type |  
      Lithium 3.6V  
        (non-replaceable) |  
      
     
      | Battery Life |  
      5 years typical at  
        1 minute sample intervals |  
      
     
      | Battery Storage  
        Life |  
      >10 years  
        typical when not logging |  
      
     
      | Repairs |  
      Unit  
        non-repairable, practical life of unit, 5 years |  
      
     
      | User Calibration |  
      Zero calibration  
        with DK015 software |  
      
     
      | Sample Point  
        Storage* |  
      7936 measurements |  
      
     
      | Download Time |  
      45 seconds, typical  
        with logger full |  
      
     
      | Response Time |  
      DK976517: 15 min.  
        to 63% of Full Scale, typical;  
        DK976516/DK976525: 5 min. to 63% of Full Scale, typical |  
      
     
      | Resolution |  
      0.1 ¡ÆF (0.1 ¡ÆC)  
        at +70 ¡ÆF; 1 ¡ÆF (0.6 ¡ÆC) over range -40 to +257 ¡ÆF (-40 to +125 ¡ÆC) |  
      
     
      | Approvals |  
      CE |  
      
     
      | Enclosure Type |  
      316 Stainless Steel |  
      
     
      | Dimensions  
        (enclosure) |  
      DK976517:  
        3.69" (9.37cm) x 0.6875" (1.75cm)  
        DIA; DK976516: 6.25" (15.88cm) x 0.6875" (1.75cm)  
        DIA;DK976525: 8.69" (22.07cm) x 0.6875" (1.75cm) DIA, Probe  
        0.11" (0.28cm) DIA |  
      
     
      | Weight |  
      DK976517: 2.5oz  
        (72g); DK976516: 2.7oz (78g); DK976525: 2.7oz (78g) |  
      
     
      | DK015 -  
        SoftWare & Download Cable Specifications |  
      
     
      | Compatible With |  
      Windows¢â 95,  
        98, 2000 and NT |  
      
     
      | PC Requirements |  
      PC with 386 or  
        better microprocessor, 4M RAM, 1 free COM (serial) port, CD drive |  
      
     
      | Cable Type/Length |  
      9 pin male D-shell  
        to male 2.5mm stereo plug, 6' long |  
      
     
      | Computer Interface |  
      RS-232 COM (serial)  
        port |  
      
     
      Sofyware Version  
        Required (minimum) |  
      1.00.00.64 |  
      
     
      |  
         * Sample points  
        are a logger's data storage capacity.    
        For example, the DK976517 High Temperature Datalogger can store up to  
        7,396 sample points. If you request a temperature sample every minute,  
        it would record for 5.5 days before filling the memory, recording every  
        10 seconds would take 22 hours to fill, and so on. You can set the  
        sample rate from 10 seconds to 24 hours in 10 second increments.  
       |  
      
   
  
  
 
 
 
   
     
      | CAT  
        NO. |  
        |  
      MODEL |  
        |  
      DEscRIPTION |  
        |  
      AVAIL |  
        |  
      PRICE |  
      
   
  
 
 
   
     
      | DK976525 |  
        |  
      A202 |  
        |  
      100' Straight  
        Extension Cable (FT121 only) |  
        |  
      Yes |  
        |  
      861,840 
     |  
  
 
  
    
      | DK976516 | 
        | 
      HT120 | 
        | 
      High  
        Temperature Datalogger w/Probe |  
        |  
      Yes |  
        |  
      753,840 
     |  
  
 
  
    
      | DK976517 | 
        | 
      HT100 | 
        | 
      High  
        Temperature Datalogger |  
        |  
      Yes |  
        |  
      732,240 
     |  
  
 
  
    
      | DK015 | 
        | 
      A015 | 
        | 
      DicksonWare¢â  
        Software and Download cable |  
        |  
      Yes |  
        |  
      170,640 
     |  
  
 
  
    
      | DK025 | 
        | 
      A025 | 
        | 
      DicksonWare¢â  
        Secure Software and Download Cable (21CFR11 compliant) |  
        |  
      Yes |  
        |  
      357,714
           
     |  
  
 
 |  |  
         
 |  
 |  
 
 
  |  |   
        
        
              | 
            
                
                
                    | ¹øÈ£ | 
                    Á¦¸ñ | 
                    ÀÛ¼ºÀÚ | 
                    ÀÛ¼ºÀÏ | 
                    Æò°¡Á¡¼ö | 
                 
                  |             
              | 
         
        
            
                 | 
                
                    ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
                    »ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. | 
                  |  
                    
              | 
             | 
              | 
         
         
        
        
        
        
        
        
     | 
 
 |  
 
 
  |  |   
        
        
              | 
            
                
                
                    | ¹øÈ£ | 
                    Á¦¸ñ | 
                    ÀÛ¼ºÀÚ | 
                    ÀÛ¼ºÀÏ | 
                    ´äº¯ | 
                 
                  | 
              | 
         
        
            
                 | 
                
                    ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù. 
                    ±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. | 
                  |  
                    
              | 
             | 
              | 
         
         
        
        
        
     | 
 
 |  
 
 
  |  |  
        
        | 
        ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. |    | 
 
 |  
 
 
 |